Skip to content
Fort Lauderdale, FL · Licensed across FloridaMon–Fri 8:00 AM – 5:00 PM · (954) 807-3208
Romco MultifamilyCall

What we build · Adaptive Reuse

Converting a Building That Was Something Else

Office, hotel or warehouse converted to residential. Occasionally excellent value and frequently more expensive than building new, and the difference is decided by the existing structure.

Bring the site, the unit count and the drawings at whatever stage. You get a range, the drivers, and an honest read on the pro forma.

Self-perform

Dewatering, SOE and deep foundations in house

Licensed

General contractor, licensed in the state of Florida

GMP

Open book, with the contingency visible to you

Draws

Documentation your lender can actually process

The floor plate decides everything

Residential needs light and air at every unit. An office floor plate designed for open plan is often too deep to yield good units without a light well or losing the core. That single geometric fact determines feasibility more than the condition of the building, and it is knowable in an afternoon.

Floor-to-floor height is the second constraint and it is as unforgiving as the plate. Residential needs to run mechanical, plumbing and drainage through ceilings that an office building never had to accommodate, and a tight floor-to-floor leaves nowhere to put any of it without losing ceiling height the units cannot spare.

What to test before anything else

  • Floor plate depth and whether units can reach light and air.
  • Floor-to-floor height, which has to absorb new MEP.
  • Existing structural capacity for residential loading and new openings.
  • What the conversion triggers — accessibility, life safety, energy.
  • Existing conditions: asbestos, undocumented alterations, dead services.

Doing the test fit properly

Lay actual unit plans onto the actual floor plate, with real corridor widths, real core positions and real light and air requirements. Not a yield calculation from the gross area — a drawn arrangement that could be built.

It takes an afternoon, it comes before the appraisal and before the pro forma, and it answers the only question that matters at that stage. If the plate does not yield units, nothing else about the building is relevant.

How we handle it

  1. 01Test-fit units against the actual floor plate before anything else.
  2. 02Survey structure and services rather than trusting as-builts.
  3. 03Establish what the change of use triggers, in writing.
  4. 04Price with a stated concealed-conditions allowance.
  5. 05Sequence to keep the envelope weathertight throughout.

Do the test fit first, before the appraisal, before the pro forma, before anything. If the plate does not yield units, nothing else about the building matters — and that answer takes an afternoon rather than a month.

Said plainly

Where we stop

If the structure needs substantial reinforcement and the conversion triggers full code compliance, new construction is frequently cheaper. We will run that comparison honestly even though the conversion is the more interesting job.

FAQ

Common questions

Is conversion cheaper than new build?
Sometimes. Frequently not, once structure and code triggers are counted. Test-fit first.
What kills most conversions?
Floor plate depth. Units that cannot reach light and air make the yield unworkable.
What gets triggered?
Accessibility, life safety and energy code, commonly across the whole building.
Are as-builts reliable?
Rarely. Survey before designing — it is much cheaper than discovering it later.

Next step

Find out what is actually wrong with it.